- Задачи
- О компании
- Статьи
- Продукция
- Внедрения
- Новости
- Контакты
Наш менеджер в течении 30 минут свяжется с вами
CelciuXº предназначен для обеспечения функций связи, не требующих программирования, при помощи ПЛК и ЧМИ Omron и других производителей. А самое главное – CelciuXº (EJ1) включает все простые в использовании и интеллектуальные технологии контроля температуры, включая 2-PID, компенсацию возмущения и различные способы настройки.
Type | Control points | Control outputs | Auxiliary outputs | Other functions | Terminal | Order code |
---|---|---|---|---|---|---|
Basic unit | 2 | 2 voltage (pulse) | 2 transistor (NPN) 2 For heating/cooling control applications, the auxiliary outputs on the 2-point models are used for cooling control. On the 4-point models, heating/cooling control can be performed for two input points only. | 2 CT input 2 + 2 event inputWhen using the heater burnout alarm, purchase a Current Transformer (E54-CT1 or E54-CT3) separately. | M3 screws | EJ1N-TC2A-QNHB |
Basic unit | 2 | 2 voltage (pulse) | 2 transistor (NPN) 2 For heating/cooling control applications, the auxiliary outputs on the 2-point models are used for cooling control. On the 4-point models, heating/cooling control can be performed for two input points only. | 2 CT input 2 + 2 event inputWhen using the heater burnout alarm, purchase a Current Transformer (E54-CT1 or E54-CT3) separately. | Screw-less clamp | EJ1N-TC2B-QNHB |
Basic unit | 2 | 2 current | 2 transistor (NPN) 2 For heating/cooling control applications, the auxiliary outputs on the 2-point models are used for cooling control. On the 4-point models, heating/cooling control can be performed for two input points only. | 2 event input | M3 screws | EJ1N-TC2A-CNB |
Basic unit | 2 | 2 current | 2 transistor (NPN) 2 For heating/cooling control applications, the auxiliary outputs on the 2-point models are used for cooling control. On the 4-point models, heating/cooling control can be performed for two input points only. | 2 event input | Screw-less clamp | EJ1N-TC2B-CNB |
Basic unit | 4 | 4 voltage (pulse) | – | – | M3 screws | EJ1N-TC4A-QQ |
Basic unit | 4 | 4 voltage (pulse) | – | – | Screw-less clamp | EJ1N-TC4B-QQ |
High function unit | – | – | 4 transistor (NPN) | 4 event input | M3 screws | EJ1N-HFUA-NFLK |
High function unit | – | – | 4 transistor (NPN) | 4 event input | Screw-less clamp | EJ1N-HFUB-NFLK |
DeviceNet unit | – | – | – | – | Screw connector | EJ1N-HFUB-DRT |
Ethernet unit 2 This unit mounts to the left of the CelciuX° (EJ1) configuration and enables PROFINET or Modbus/TCP network connection. Combine the HFU-ETN with an EDU_-NFLK end unit to use with other devices supporting Modbus-RTU like E5_N temperature controllers and MX2 Inverters. | – | – | – | – | 3 x RJ45 | EJ1N-HFU-ETN |
End unit 2 An End unit is always required for connection to a Basic unit or an HFU. An HFU cannot operate without a Basic unit. | – | – | 2 transistor (NPN) | – | M3 screws | EJ1C-EDUA-NFLK |
End unit 2 An End unit is always required for connection to a Basic unit or an HFU. An HFU cannot operate without a Basic unit. | – | – | 2 transistor (NPN) | – | Removable Connector | EJ1C-EDUC-NFLK |
Diameter | Order code |
---|---|
5.8 dia. | E54-CT1 |
12.0 dia. | E54-CT3 |
Description | Order code |
---|---|
G3ZA connecting cable 5 meter | EJ1C-CBLA050 |
USB programming cable | E58-CIFQ1 |
PC based configuration and tuning software CX-Thermo | EST2-2C-MV4 |
PROFIBUS Gateway | PRT1-SCU11 |
Item | Type | EJ1_-TC2 | EJ1_-TC4 |
---|---|---|---|
Power supply voltage | 24 VDC | ||
Operating voltage range | 85% to 110% of rated voltage | ||
Power consumption | 4 W max. (at maximum load) | 5 W max. (at maximum load) | |
Input (see note) 2 Inputs are fully multi-input. Therefore, platinum resistance thermometer, thermocouple, infrared thermosensor, and analog input can be selected. | Thermocouple: K, J, T, E, L, U, N, R, S, B, W, PLII ES1B Infrared Thermosensor: 10 to 70°C, 60 to 120°C, 115 to 165°C, 140 to 260°C. Analog input: 4 to 20 mA, 0 to 20 mA, 1 to 5 V, 0 to 5 V, 0 to 10 VPlatinum resistance thermometer: Pt100, JPt100 | ||
Input impedance | Current input: 150Ω max., voltage input: 1 MΩ min. | ||
Control outputs | Voltage output | Output voltage: 12 VDC ±15%, max. load current: 21 mA (PNP models with short-circuit protection circuit) | |
Transistor output | Max. operating voltage: 30 V, max. load current: 100 mA | – | |
Current output | Current output range: 4 to 20 mA or 0 to 20 mA DC Load: 500 Ω max. (including transfer output)(Resolution: Approx: 2,800 for 4 to 20 mA DC, approx. 3,500 for 0 to 20 mA DC) | – | |
Event inputs | Input points | 2 | – |
Contact input | ON: 1 kΩ max., OFF. 100 kΩ min. | – | |
Non-contact input | ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max. | – | |
Outflow current: approx. 4 mA per point | – | ||
Number of input and control points | Input points: 2, control points: 2 | Input points: 4, control points: 4 | |
Setting method | Via communications | ||
Control method | ON/OFF control or 2-PID (with autotuning, selftuning, Heat & Cool autotuning and non-linear cool output selection) | ||
Other functions | Two-point input shift, digital input filter, remote SP, SP ramp, manual manipulated variable, manipulated variable limiter, interference overshoot adjustment, loop burnout alarm, RUN/STOP, banks, I/O allocations, etc. | ||
Alarm output | 2 points via End unit | ||
Communication | RS-485, PROFIBUS, Modbus, DeviceNet | RS-485, PROFIBUS, Modbus, DeviceNet | |
Size in mm (W×H×D) | 31×96×109 | ||
Weight | 180 g | ||
Ambient temperature range | Operating –10 to 55°C, Storage –25 to 65°C (with no icing or condensation) | ||
Ambient humidity range | Operating 25% to 85% (with no condensation) |
Item | Size in mm (H×W×D) |
---|---|
EJ1N-HFU_-NFL_ | 95.4×31.0×104.9/109.0 |
EJ1N-HFUB-DRT | 90.9×31.0×82.2 |
EJ1C-EDU | 95.4×15.7×76.2/79.7 |
Надежность, компактность и бескомпромиссные характеристики регулирования делают CelciuX° идеальным средством для решения базовых задач многоконтурного регулирования.
Регулирование, визуализация и протоколирование данных — нет более простого решения, чем прямое подключение CelciuX° к терминалу HMI компании Omron.