Встроенные функции безопасности: кат. безопасности 3 по EN954-1, SIL II по EN6158 и кат. останова 0 по EN60204-1
CE, UL, cUL и TUV
Номинальные параметры
Класс 200 В, однофазные, от 0,1 до 4 кВт
Класс 200 В, трехфазные, от 0,1 до 15 кВт
Класс 400 В, трехфазные, от 0,2 до 15 кВт
Ordering information
V1000
Specifications
Order code
Heavy Duty
Normal Duty
Standard
Built-in filter
1x200 V
0.12 kW
0.8 A
0.18 kW
0.8 A
VZAB0P1BAA
VZAB0P1EAB
0.25 kW
1.6 A
0.37 kW
1.6 A
VZAB0P2BAA
VZAB0P2EAB
0.55 kW
3.0 A
0.75 kW
3.5 A
VZAB0P4BAA
VZAB0P4EAB
1.1 kW
5.0 A
1.1 kW
6.0 A
VZAB0P7BAA
VZAB0P7EAB
1.5 kW
8.0 A
2.2 kW
9.6 A
VZAB1P5BAA
VZAB1P5EAB
2.2 kW
11.0 A
3.0 kW
12.0 A
VZAB2P2BAA
VZAB2P2EAB
4.0 kW
17.5 A
5.5 kW
21.0 A
VZAB4P0BAA
−
3x200 V
0.12 kW
0.8 A
0.18 kW
0.8 A
VZA20P1BAA
−
0.25 kW
1.6 A
0.37 kW
1.6 A
VZA20P2BAA
−
0.55 kW
3.0 A
0.75 kW
3.5 A
VZA20P4BAA
−
1.1 kW
5.0 A
1.1 kW
6.0 A
VZA20P7BAA
−
1.5 kW
8.0 A
2.2 kW
9.6 A
VZA21P5BAA
−
2.2 kW
11.0 A
3.0 kW
12.0 A
VZA22P2BAA
−
4.0 kW
17.5 A
5.5 kW
21.0 A
VZA24P0BAA
−
5.5 kW
25.0 A
7.5 kW
30.0 A
VZA25P5FAA
−
7.5 kW
33.0 A
11.0 kW
40.0 A
VZA27P5FAA
−
11 kW
47.0 A
15.0 kW
56.0 A
VZA2011FAA
−
15 kW
60.0 A
18.5 kW
69.0 A
VZA2015FAA
−
3x400 V
0.37 kW
1.2 A
0.37 kW
1.2 A
VZA40P2BAA
VZA40P2EAB
0.55 kW
1.8 A
0.75 kW
2.1 A
VZA40P4BAA
VZA40P4EAB
1.1 kW
3.4 A
1.5 kW
4.1 A
VZA40P7BAA
VZA40P7EAB
1.5 kW
4.8 A
2.2 kW
5.4 A
VZA41P5BAA
VZA41P5EAB
2.2 kW
5.5 A
3.0 kW
6.9 A
VZA42P2BAA
VZA42P2EAB
3.0 kW
7.2 A
4.0 kW
8.8 A
VZA43P0BAA
VZA43P0EAB
4.0 kW
9.2 A
5.5 kW
11.1 A
VZA44P0BAA
VZA44P0EAB
5.5 kW
14.8 A
7.5 kW
17.5 A
VZA45P5FAA
−
7.5 kW
18.0 A
11.0 kW
23.0 A
VZA47P5FAA
−
11 kW
24.0 A
15.0 kW
31.0 A
VZA4011FAA
−
15 kW
31.0 A
18.5 kW
38.0 A
VZA4015FAA
−
① Line filters
Inverter
Standard line filter
Low leakage line filter
Schaffner
Rasmi
Schaffner
Rasmi
Voltage
Model VZA⬜
Reference
A1000-FIV
Current (A)
Reference
A1000-FIV
Current (A)
Reference
A1000-FIV
Current (A)
Reference
A1000-FIV
Current (A)
1-Phase
200 VAC
B0P1 / B0P2 / B0P4
1010-SE
10
1010-RE
10
1010-SE-LL
10
1010-RE-LL
10
B0P7 / B1P5
1020-SE
20
1020-RE
20
1020-SE-LL
20
1020-RE-LL
20
B2P2
1030-SE
30
1030-RE
30
1030-SE-LL
24
1030-RE-LL
30
B4P0
1040-SE
40
1040-RE
40
1040-SE-LL
40
1040-RE-LL
40
3-Phase
200 VAC
20P1 / 20P2 / 20P4 / 20P7
2010-SE-V1
10
2010-RE
10
2010-SE-LL
10
2010-RE-LL
10
21P5 / 22P2
2020-SE
14
2020-RE
16
2020-SE-LL
20
2020-RE-LL
16
24P0
2030-SE
24
2030-RE
26
2030-SE-LL
30
2030-RE-LL
26
25P5 / 27P5
2060-SE-V1
52
2060-RE
60
−
−
2060-RE-LL
60
2011
2080-SE-V1
68
2080-RE
80
−
−
2080-RE-LL
80
2015
2100-SE-V1
80
2100-RE
100
−
−
2100-RE-LL
100
3-Phase
400 VAC
40P2 / 40P4
3005-SE
5
3005-RE
5
3005-SE-LL
5
3005-RE-LL
5
40P7 / 41P5 / 42P2 / 43P0
3010-SE
10
3010-RE
10
3010-SE-LL
10
3010-RE-LL
10
44P0
3020-SE
15
3020-RE
15
3020-SE-LL
15
3020-RE-LL
15
45P5 / 47P5
3030-SE-V1
30
3030-RE
30
3030-SE-LL
30
3030-RE-LL
30
4011 / 4015
3050-SE-V1
50
3050-RE
50
3050-SE-LL
50
3050-RE-LL
50
① Input AC reactors
Inverter
AC Reactor
Voltage
Model VZA ⬜
Reference
1-Phase 200 VAC
B0P1 / B0P2 / B0P4
AX-RAI02000070-DE
B0P7
AX-RAI01700140-DE
B1P5
AX-RAI01200200-DE
B2P2
AX-RAI00630240-DE
B4P0
−
3-Phase 200 VAC
20P1 / 20P2 / 20P4 / 20P7
AX-RAI02800080-DE
21P5 / 22P2 / 24P0
AX-RAI00880200-DE
25P5 / 27P5
AX-RAI00350335-DE
2011 / 2015
AX-RAI00180670-DE
3-Phase 400 VAC
40P2 / 40P4 / 40P7 / 41P5
AX-RAI07700050-DE
42P2 / 43P0 / 44P0
AX-RAI03500100-DE
45P5 / 47P5
AX-RAI01300170-DE
4011 / 4015
AX-RAI00740335-DE
① DC reactors
200V 1-phase
200V 3-phase
400V 3-phase
Model VZA ⬜
DC Reactor
Model VZA ⬜
DC Reactor
Model VZA ⬜
DC Reactor
B0P1
AX-RC10700032-DE
20P1
AX-RC21400016-DE
40P2 / 40P4
AX-RC43000020-DE
B0P2
20P2
40P7
AX-RC27000030-DE
B0P4
AX-RC06750061-DE
20P4
AX-RC10700032-DE
41P5
AX-RC14000047-DE
B0P7
AX-RC03510093-DE
20P7
AX-RC06750061-DE
42P2
AX-RC10100069-DE
B1P5
AX-RC02510138-DE
21P5
AX-RC03510093-DE
43P0
AX-RC08250093-DE
B2P2
AX-RC01600223-DE
22P2
AX-RC02510138-DE
44P0
AX-RC06400116-DE
B4P0
−
24P0
AX-RC01600223-DE
45P5
AX-RC04410167-DE
-
25P5
AX-RC01110309-DE
47P5
AX-RC03350219-DE
27P5
AX-RC00840437-DE
4011
AX-RC02330307-DE
2011
AX-RC00590614-DE
4015
AX-RC01750430-DE
2015
AX-RC00440859-DE
−
① Chokes
Model
Diameter
Description
AX-FER2102-RE
21
For 2.2 KW motors or below
AX-FER2515-RE
25
For 15 KW motors or below
AX-FER5045-RE
50
For 45 KW motors or below
① Output AC reactor
Inverter
AC Reactor
Voltage
Model VZA ⬜
Reference
200 VAC
B0P1 / B0P2 / B0P4
20P1 / 20P2 / 20P4
AX-RAO11500026-DE
B0P7 / 20P7
AX-RAO07600042-DE
B1P5 / 21P5
AX-RAO04100075-DE
B2P2 / 22P2
AX-RAO03000105-DE
B4P0 / 24P0
AX-RAO01830160-DE
25P5
AX-RAO01150220-DE
27P5
AX-RAO00950320-DE
2011
AX-RAO00630430-DE
2015
AX-RAO00490640-DE
400 VAC
40P2 / 40P4 / 40P7 / 41P5
AX-RAO16300038-DE
42P2
AX-RAO11800053-DE
43P0 / 44P0
AX-RAO07300080-DE
45P5
AX-RAO04600110-DE
47P5
AX-RAO03600160-DE
4011
AX-RAO02500220-DE
4015
AX-RAO02000320-DE
② Communication cards
Type
Description
Function
Order code
Communication option board
DeviceNet option card
Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through DeviceNet communication with the host controller.
SI-N3/V
PROFIBUS-DP option card
Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through PROFIBUS-DP communication with the host controller.
SI-P3/V
CANopen option card
Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through CANopen communication with the host controller.
SI-S3/V
MECHATROLINK-II option card
Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through MECHATROLINK-II communication with the host controller.
SI-T3/V
EtherCAT option card
Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through EtherCAT communication with the host controller.
EUOP-SI-ES3/V
PROFINET option card
Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through PROFINET communication with the host controller.
SI-EP3/V
③ Accessories
Types
Description
Functions
Order code
Digital operator
LCD remote operator
LCD Display operator with language support
JVOP-180
Remote operator cable
3 meters cable for connecting remote operator
A1000-CAVOP300-EE
Accessories
USB converter / USB cable
USB converter unit with copy and backup function
JVOP-181
24 VDC option board
24VDC control board power supply VZA-B/2/4 from 0.1 to 4 KW
PS-V10S
24VDC control board power supply VZA-2/4 from 5.5 to 15 KW
PS-V10M
PC connection cable
RS232 PC tool connection cable
A1000-CAVPC232-EE
④ Computer software
Types
Description
Installation
Order code
Software
Computer software
Configuration and monitoring software tool
CX-Drive
Computer software
Configuration and monitoring software tool
CX-One
⑤ Braking unit, braking resistor unit
Inverter
Braking resistor unit
Voltage
Max. motor kW
Inverter model VZA⬜
Connectable min.
resistance Ω
Inverter mounted type
(3 %ED, 10 sec max)
Braking
torque %
1-phase
3-phase
Type AX-
Resist Ω
200 V (single-/
three-phase)
0.12
B0P1
20P1
300
REM00K1400-IE
400
135
0.25
B0P2
20P2
120
0.55
B0P4
20P4
200
REM00K1200-IE
200
120
1.1
B0P7
20P7
120
70
1.5
B1P5
21P5
60
REM00K2070-IE
70
190
2.2
B2P2
22P2
120
4.0
B4P0
24P0
32
REM00K4035-IE
35
135
5.5
−
25P5
16
75
7.5
−
27P5
9.6
55
11
−
2011
REM00K6035-IE
35
40
15
−
2015
REM00K9017-IE
17
55
400 V (three-phase)
0.37
−
40P2
750
2 x REM00K1400-IE
800
270
0.55
−
40P4
270
1.1
−
40P7
510
270
1.5
−
41P5
240
REM00K1400-IE
400
130
2.2
−
42P2
200
REM00K2200-IE
200
130
3.0
−
43P0
100
REM00K2120-IE
120
215
4.0
−
44P0
160
5.5
−
45P5
32
REM00K4035-IE
35
140
7.5
−
47P5
80
11
−
4011
20
REM00K6035-IE
35
50
15
−
4015
REM00K9020-IE
20
55
⑥ Mounting accessories
Types
Description
Applicable models VZA ⬜
Order code
DIN Rail
Necessary to mount the inverter on a DIN rail
B0P1/B0P2/B0P4
20P1/20P2/20P4/20P7
EZZ08122A
B0P7/B1P5
21P5/22P2
40P2/40P4/40P7/41P5/42P2
EZZ08122B
B2P2
24P0
44P0
EZZ08122C
B4P0
EZZ08122D
Heatsink external mounting attachment
Additional items to mount the inverter with the heatsink out of the panel
V1000 + Option board (Communication and 24 VDC power supply)
Built-in filter
VZA ⬜
Dimensions in mm
W
H
H1
D1
D2
D
B0P1
68+
178
50
69.5
6.5
76
B0P2
B0P4
79.5
38.5
118
B0P7
108
77.9
59.6
137.5
B1P5
89.4
64.6
154
B2P2
140
183
55
96.4
66.6
163
40P2
108
178
50
69.4
11.6
81
40P4
29.6
99
40P7
77.9
59.6
137.5
41P5
94.4
154
42P2
43P0
44P0
140
183
55
76.4
66.6
143
1.Only HD settings is available for this model
2.Based on a standard 4-pole motor for maximum applicable motor output: Heavy Duty (HD) mode with a 150% overload capacity Normal Duty (ND) mode with a 120% overload capacity
3.Based on a standard 4-pole motor for maximum applicable motor output: Heavy Duty (HD) mode with a 150% overload capacity Normal Duty (ND) mode with a 120% overload capacity
1.Only HD settings is available for this model
2.Based on a standard 4-pole motor for maximum applicable motor output: Heavy Duty (HD) mode with a 150% overload capacity Normal Duty (ND) mode with a 120% overload capacity
3.Based on a standard 4-pole motor for maximum applicable motor output: Heavy Duty (HD) mode with a 150% overload capacity Normal Duty (ND) mode with a 120% overload capacity
Сэкономьте свое время и упростите конфигурирование, пуско-наладку и обслуживание инверторов и сервоприводов, используя единый программный инструмент. CX-Drive поддерживает особенности новых серий сервоприводов Accurax G5 и инвертора MX2.
CX-One - это объединенный комплект программного обеспечения с единым лицензионным номером. Установив однажды CX-One, пользователь сможет создавать, конфигурировать и программировать множество различных устройств, таких как ПЛК, ЧМИ или системы многоосного управления перемещениями, а также сети. CX-One значительно упрощает работу инженера и сводит к минимуму необходимость обучения программированию или конфигурированию систем автоматизации.