- Задачи
- О компании
- Статьи
- Продукция
- Внедрения
- Новости
- Контакты
Наш менеджер в течении 30 минут свяжется с вами
Контроллер серии NJ1 представляет собой новый контроллер Sysmac программно-логистического управления и управления движением, предназначенный для установки в компактные машины.
Note: Power supply units for the CJ Series cannot be used as a power supply for a CPU rack of the NJ System or as a power supply for an expansion rack.
Note: The end cover unit CJ1W-TER01 is included with the CPU unit.
Note: MIL = Connector according to MIL-C-83503 (compatible with DIN 41651/IEC 60603-1).
Accuracy1 | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Universal inputs, with zero/span adjustment, configurable alarms, scaling, sensor error detection | ||||||||||||
Offset/gain adjustment, scaling, peak hold, moving average, alarms, output hold | ||||||||||||
All inputs individually isolated, configurable alarms, maintenance functions, user-defined scaling, zero/span adjustment | ||||||||||||
Configurable alarms, maintenance functions, user-defined scaling, zero/span adjustment, square root, totaliser | ||||||||||||
Basic I/O unit, setup by DIP switches, adjustable filtering | ||||||||||||
Basic I/O unit, setup by DIP switches, adjustable filtering | ||||||||||||
CJ1W-EIP212 | |||||||||
CJ1W-ECT213 | |||||||||
CJ1W-CRM214 | |||||||||
RS-232C to RS-422A/RS-485 signal converter. Mounts directly on serial port |
0.265 | 0.131 | |||||||
Note: The data transfer function using intelligent I/O commands can not be used.
Note: Mount to the right of the power supply unit.
![]() | Quality of Service (QoS): EtherNet/IP control data priority. Failure detection: Broadcast storm and LSI error detection 10/100 BASE-TX, Auto-Negotiation | ||||||
Cable with connectors on both ends ![]() | |||||||
Cable with connectors on both ends ![]() | |||||||
Cable with connectors on both ends (RJ45/RJ45) ![]() | |||||||
Cable sheath material: PUR1 | Cable with connectors on both ends (RJ45/RJ45) ![]() | ||||||
Cable with connectors on both ends (RJ45/RJ45) ![]() | |||||||
Cable with connectors on both ends (M12 straight/RJ45) ![]() | |||||||
Cable with connectors on both ends (M12 L right angle/RJ45) ![]() | |||||||
Cat 5, SF/UTP, 4 × 2 × AWG 24/1 (solid core), Polyurethane (PUR) | |||||||
Cat 5, SF/UTP, 4 × 2 × AWG 26/7 (stranded core), Polyurethane (PUR) | |||||||
DIN-rail mount socket to terminate installation cable in the cabinet |
Note: Please be careful while cable processing, for EtherCAT, connectors on both ends should be shield connected and for EtherNet/IP, connectors on only one end should be shield connected.
![]() | ||||
Note: Special versions are available for USA, Canada, China and Japan.
SYSMAC-SE2___8 |
1. Accuracy for voltage and current inputs/outputs as percentage of full scale and typical value at 25°C ambient temperature (consult the operation manual for details)
Accuracy for temperature inputs/outputs as percentage of process value and typical value at 25°C ambient temperature (consult the operation manual for details)
2. Supported only by the EtherNet/IP units with unit version 2.1 or later, CPU units with unit version 1.01 or later and the Sysmac Studio version 1.02 or higher.
3. Supported only by the CPU units with unit version 1.10 or higher and the Sysmac Studio version 1.13 or higher.
4. Supported only by the CPU units with unit version 1.01 or higher and the Sysmac Studio version 1.02 or higher.
1. Accuracy for voltage and current inputs/outputs as percentage of full scale and typical value at 25°C ambient temperature (consult the operation manual for details)
Accuracy for temperature inputs/outputs as percentage of process value and typical value at 25°C ambient temperature (consult the operation manual for details)
2. Supported only by the EtherNet/IP units with unit version 2.1 or later, CPU units with unit version 1.01 or later and the Sysmac Studio version 1.02 or higher.
3. Supported only by the CPU units with unit version 1.10 or higher and the Sysmac Studio version 1.13 or higher.
4. Supported only by the CPU units with unit version 1.01 or higher and the Sysmac Studio version 1.02 or higher.