Codes and Standards | IEC 60947-5-3:2013, EN 60947-5-1:2004 + AC:2005 + A1:2009, EN 60947-1:2007 + A1:2011, EN ISO 13849-1:2008 + AC:2009, EN 62061:2005 + AC:2010 + A1:2013, ISO 14119:2013, UL508 |
Safety Classification and Reliability Data | Minimum Switched Current | 10 VDC 1 mA |
Dielectric Withstand | 250 VAC |
Insulation Resistance | 100 M Ω |
Shock Resistance | 11 ms 30G |
Vibration Resistance | 10 to 55 Hz, 1 mm amplitude |
Switching Distance | S ao 1 mm Close; S ar 10 mm Open |
Misalignment | Between switch and actuator, 2 mm in any direction |
Switching Frequency | 1.0 Hz maximum |
Response Time (On –> Off) | 10 ms max. |
Operating Time (Off –> On) | 150 ms |
Approach Speed | 200 to 1000 mm/s |
Body Material | D40ML-P_: Plastic D40ML-M_: Diecast Metal D40ML-SS_: 316 Stainless Steel Actuator Seal: Silicone Encapsulation: High Temperature Epoxy |
Operating Temperature Range | –25 to 40°C |
Ambient Operating Humidity | up to 90% at 25 ~ 40°C |
Enclosure Protection | IP67 (Plastic or Diecast Metal) IP69K (Stainless steel versions with flying leads) |
Cable Type | PVC 8 core, 6 mm outer diameter |
Mounting Bolts | 2 × M5 Tightening torque 1.0 Nm |
Mounting Position | Any |
Power Supply | 24 VDC ±10% (selv / pelv) |
Power Consumption | Unlocked: 50 mA max. Locked: - Medium Duty 325 mA max.
- Heavy Duty 500 mA max.
|
Holding Force | Medium Duty - Stainless Steel: F1 max (typical) 600 N, F zh 450 N
- Plastic and Diecast: F1 max (typical) 900 N, F zh 675 N
Heavy Duty - Stainless Steel: F1 max (typical) 950 N, F zh 700 N
- Plastic and Diecast: F1 max (typical) 1500 N, F zh 1150 N
|
Max. Switched Current (Outputs) | 200 mA (min. internal resistance 8.5 Ohms) |
Auxiliary Signal | +24 VDC (Door Open) |
Characteristic Data according to EN ISO13849-1 | PLe: If both channels are used in combination with a SIL3/PLe control device Category: Cat. 4 MTTFd: 1100a Diagnostic Coverage DC: 99% (high) Number of operating days per year: d op = 365d Number of operating hours per day: h op = 24h B10d: Not mechanical parts implemented |
Characteristic Data according to IEC62061 (used as a sub system) | Safety Integrity Level: SIL3 PFH (1/h): 4.77E-10 Corresponds to 4.8% of SIL3 PFD: 4.18E-05 Corresponds to 4.2% of SIL3 Proof Test Interval T 1 : 20a |
Information with regard to UL508 | Use LVLC or Class 2 supply. Type 1 enclosure. |
Risk Time in accordance with EN 60947-5-3 | 150 ms (switching off delay at removal of actuator) |