Housing | Release key type | Wiring method | Solenoid voltage/Indicator | Lock and release type | Contact configuration (door open/closed detection switch and lock monitor switch contacts) | Conduit size | Order code |
Head Resin/ Body Resin | Standard (metal) | Connector | 24 VDC (Orange) | Mechanical lock Solenoid release | 6-contact Model Insert the built-in switch (N, P, Q or R) into the blank _. | M20 | D4SL-N4_FA-DN |
5-contact Model Insert the built-in switch (E, F, G or H) into the blank _. | M20 | D4SL-N4_FA-DN |
24 VDC (without indicator) | 4-contact Model Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank _. | M20 | D4SL-N4_FA-N |
Terminal block | 24 VDC (Orange) | 6-contact Model Insert the built-in switch (N, P, Q or R) into the blank _. | M20 | D4SL-N4_FA-D |
5-contact Model Insert the built-in switch (E, F, G or H) into the blank _. | M20 | D4SL-N4_FA-D |
24 VDC (without indicator) | 4-contact Model Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank _. | M20 | D4SL-N4_FA |
Connector | 24 VDC (Orange) | Solenoid lock Mechanical release | 6-contact Model Insert the built-in switch (N, P, Q or R) into the blank _. | M20 | D4SL-N4_FG-DN |
5-contact Model Insert the built-in switch (E, F, G or H) into the blank _. | M20 | D4SL-N4_FG-DN |
24 VDC (without indicator) | 4-contact Model Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank _. | M20 | D4SL-N4_FG-N |
Terminal block | 24 VDC (Orange) | 6-contact Model Insert the built-in switch (N, P, Q or R) into the blank _. | M20 | D4SL-N4_FG-D |
5-contact Model Insert the built-in switch (E, F, G or H) into the blank _. | M20 | D4SL-N4_FG-D |
24 VDC (without indicator) | 4-contact Model Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank _. | M20 | D4SL-N4_FG |
Degree of protection | IP67 (EN60947-5-1) |
Durability | Mechanical | 1,000,000 operations min. |
Electrical | 150,000 operations min. (1 A resistance at 125 VAC) |
Operating speed | 0.05 to 1 m/s |
Operating frequency | 5 operations minute max. |
Direct opening force | 60 N min. (EN60947-5-1) |
Direct opening travel4 | 15 mm min. (EN60947-5-1) |
Holding force | 1,300 N min. |
Minimum applicable load | 1 mA resistive load at 5 VDC (N-level reference value) |
Rated insulation voltage (Ui) | 150 V (EN60947-5-1) |
Rated frequency | 50/60 Hz |
Protection against electric shock | Class II (double insulation) |
Pollution degree (operating environment) | 3 (EN60947-5-1) |
Conditional short-circuit current | 100 A (EN60947-5-1) |
Conventional free air thermal current (Ith) | 2.5 A (11-42, 21-52, 21-22) 1 A (Others) |
Ambient operating temperature | − 10 to 55 ° C (with no icing) |
Ambient operations humidity | 95% max. |