Appearance | Sensing distance | Connection method | Cable specifications | Polarity | Order code |
Operation mode: NO | Operation mode: NC |
Shielded | M8 | 3 mm | Pre-wired Models (2 m) , , | Vinyl chloride (PVC) (oil-resistant reinforced) | Yes | E2E-X3D18 2M | E2E-X3D28 2M |
No | E2E-X3D18-T 2M | E2E-X3D28-T 2M |
M12 Pre-wired Smartclick Connector Models (0.3 m) | Yes | E2E-X3D18-M1TGJ 0.3M | E2E-X3D28-M1TGJ 0.3M |
No | E2E-X3D18-M1TGJ-T 0.3M | E2E-X3D28-M1TGJ-T 0.3M |
M12 | 7 mm | Pre-wired Models (2 m)1 , 2 , 3 | Yes | E2E-X7D112 2M | E2E-X7D212 2M |
No | E2E-X7D112-T 2M | E2E-X7D212-T 2M |
M12 Pre-wired Smartclick Connector Models (0.3 m) | Yes | E2E-X7D112-M1TGJ 0.3M | E2E-X7D212-M1TGJ 0.3M |
No | E2E-X7D112-M1TGJ-T 0.3M | E2E-X7D212-M1TGJ-T 0.3M |
M18 | 11 mm | Pre-wired Models (2 m)1 , 2 , 3 | Yes | E2E-X11D118 2M | E2E-X11D218 2M |
No | E2E-X11D118-T 2M | E2E-X11D218-T 2M |
M12 Pre-wired Smartclick Connector Models (0.3 m) | Yes | E2E-X11D118-M1TGJ 0.3M | E2E-X11D218-M1TGJ 0.3M |
No | E2E-X11D118-M1TGJ-T 0.3M | E2E-X11D218-M1TGJ-T 0.3M |
M30 | 20 mm | Pre-wired Models (2 m) 1 , 2 , 3 | Yes | E2E-X20D130 2M | E2E-X20D230 2M |
No | E2E-X20D130-T 2M | E2E-X20D230-T 2M |
M12 Pre-wired Smartclick Connector Models (0.3 m) | Yes | E2E-X20D130-M1TGJ 0.3M | E2E-X20D230-M1TGJ 0.3M |
No | E2E-X20D130-M1TGJ-T 0.3M | E2E-X20D230-M1TGJ-T 0.3M |
Unshielded | M8 | 6 mm | Pre-wired Models (2 m) 1 , 2 , 3 | Yes | E2E-X6MD18 2M | E2E-X6MD28 2M |
No | E2E-X6MD18-T 2M | E2E-X6MD28-T 2M |
M12 Pre-wired Smartclick Connector Models (0.3 m) | Yes | E2E-X6MD18-M1TGJ 0.3M | E2E-X6MD28-M1TGJ 0.3M |
No | E2E-X6MD18-M1TGJ-T 0.3M | E2E-X6MD28-M1TGJ-T 0.3M |
M12 | 10 mm | Pre-wired Models (2 m) 1 , 2 , 3 | Yes | E2E-X10MD112 2M | E2E-X10MD212 2M |
No | E2E-X10MD112-T 2M | E2E-X10MD212-T 2M |
M12 Pre-wired Smartclick Connector Models (0.3 m) | Yes | E2E-X10MD112-M1TGJ 0.3M | E2E-X10MD212-M1TGJ 0.3M |
No | E2E-X10MD112-M1TGJ-T 0.3M | E2E-X10MD212-M1TGJ-T 0.3M |
M18 | 20 mm | Pre-wired Models (2 m) 1 , 2 , 3 | Yes | E2E-X20MD1L18 2M | E2E-X20MD2L18 2M |
No | E2E-X20MD1L18-T 2M | E2E-X20MD2L18-T 2M |
M12 Pre-wired Smartclick Connector Models (0.3 m) | Yes | E2E-X20MD1L18-M1TGJ 0.3M | E2E-X20MD2L18-M1TGJ 0.3M |
No | E2E-X20MD1L18-M1TGJ-T 0.3M | E2E-X20MD2L18-M1TGJ-T 0.3M |
M30 | 40 mm | Pre-wired Models (2 m) 1 , 2 , 3 | Yes | E2E-X40MD1L30 2M | E2E-X40MD2L30 2M |
No | E2E-X40MD1L30-T 2M | E2E-X40MD2L30-T 2M |
M12 Pre-wired Smartclick Connector Models (0.3 m) | Yes | E2E-X40MD1L30-M1TGJ 0.3M | E2E-X40MD2L30-M1TGJ 0.3M |
No | E2E-X40MD1L30-M1TGJ-T 0.3M | E2E-X40MD2L30-M1TGJ-T 0.3M |
Appearance | Sensing distance | Connection method | Cable specifications | Polarity | Order code |
Operation mode: NO | Operation mode: NC |
Shielded | M8 | 1.5 mm | Pre-wired Models (2 m) , , | Vinyl chloride (PVC) (oil-resistant reinforced) | Yes | E2E-X1R5D1-N 2M | E2E-X1R5D2-N 2M |
No | E2E-X1R5D1-T-N 2M | E2E-X1R5D2-T-N 2M |
M12 Pre-wired Smartclick Connector Models (0.3 m) | Yes | E2E-X1R5D1-M1TGJ 0.3M | E2E-X1R5D2-M1TGJ 0.3M |
No | E2E-X1R5D1-M1TGJ-T 0.3M | E2E-X1R5D2-M1TGJ-T 0.3M |
M12 | 2.5 mm | Pre-wired Models (2 m)1 , 2 , 3 | Yes | E2E-X2R5D1-N 2M | E2E-X2R5D2-N 2M |
No | E2E-X2R5D1-T-N 2M | E2E-X2R5D2-T-N 2M |
M12 Pre-wired Smartclick Connector Models (0.3 m) | Yes | E2E-X2R5D1-M1TGJ 0.3M | E2E-X2R5D2-M1TGJ 0.3M |
No | E2E-X2R5D1-M1TGJ-T 0.3M | E2E-X2R5D2-M1TGJ-T 0.3M |
M18 | 5 mm | Pre-wired Models (2 m)1 , 2 , 3 | Yes | E2E-X5D1-N 2M | E2E-X5D2-N 2M |
No | E2E-X5D1-T-N 2M | E2E-X5D2-T-N 2M |
M12 Pre-wired Smartclick Connector Models (0.3 m) | Yes | E2E-X5D1-M1TGJ 0.3M | E2E-X5D2-M1TGJ 0.3M |
No | E2E-X5D1-M1TGJ-T 0.3M | E2E-X5D2-M1TGJ-T 0.3M |
| Size | M8 | M12 | M18 | M30 |
| Shielded | Shielded | Unshielded | Shielded | Unshielded | Shielded | Unshielded | Shielded | Unshielded |
Item | Model | E2E-X3D ⬜ | E2E-X6MD ⬜ | E2E-X7D ⬜ | E2E-X10MD ⬜ | E2E-X11D ⬜ | E2E-X20MD ⬜ | E2E-X20D ⬜ | E2E-X40MD ⬜ |
Sensing distance | 3 mm ±10% | 6 mm ±10% | 7 mm ±10% | 10 mm ±10% | 11 mm ±10% | 20 mm ±10% | 20 mm ±10% | 40 mm ±10% |
Setting distance | 0 to 2.4 mm | 0 to 4.8 mm | 0 to 5.6 mm | 0 to 8 mm | 0 to 8.8 mm | 0 to 16 mm | 0 to 16 mm | 0 to 32 mm |
Differential travel | 15% max. of sensing distance |
Detectable object | Ferrous metal |
Standard sensing object | Iron, 9 × 9 × 1 mm | Iron, 18 × 18 × 1 mm | Iron, 21 × 21 × 1 mm | Iron, 30 × 30 × 1 mm | Iron, 33 × 33 × 1 mm | Iron, 60 × 60 × 1 mm | Iron, 60 × 60 × 1 mm | Iron, 120 × 120 × 1 mm |
Response frequency | 1,000 Hz | 500 Hz | 800 Hz | 400 Hz | 500 Hz | 200 Hz | 200 Hz | 100 Hz |
Power supply voltage | 10 to 30 VDC, (including 10% ripple (p-p)) |
Leakage current | 0.8 mA max. |
Control output | Load current | 3 to 100 mA |
Residual voltage | Polarity: 3 V max. (Load current: 100 mA, Cable length: 2 m) No polarity: 5 V max. (Load current: 100 mA, Cable length: 2 m) |
Indicator | D1 Models: Operation indicator (orange), Setting indicator (green) D2 Models: Operation indicator (orange) |
Operation mode | D1 Models: NO D2 Models: NC |
Protection circuits | Surge suppressor, Load short-circuit protection |
Ambient temperature range | Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) |
Ambient humidity range | Operating and Storage: 35% to 95% (with no condensation) |
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ±20% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ±20% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range |
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case |
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case |
Vibration resistance (destruction) | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
Shock resistance (destruction) | 500 m/s 2 10 times each in X, Y, and Z directions | 1,000 m/s 2 10 times each in X, Y, and Z directions |
Degree of protection | Pre-wired Models/Pre-wired Connector Models: IP67 (IEC 60529), IP67G (JIS C 0920 Annex 1) Passed OMRON's Oil-resistant Component Evaluation Standards (Cutting oil type: specified in JIS K 2241:2000, Temperature: 35 °C max.) and IEC 60529 (old standard: DIN 40050 PART9) IP69K |
Connecting method | Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models (Standard cable length: 0.3 m) |
Weight (packed state) | Pre-wired Models | Approx. 60 g | Approx. 70 g | Approx. 130 g | Approx. 150 g | Approx. 180 g | Approx. 210 g |
Pre-wired Connector Models | Approx. 30 g | Approx. 40 g | Approx. 70 g | Approx. 90 g | Approx.110 g | Approx. 140 g |
Materials | Case | Nickel-plated brass | Stainless steel (SUS303) | Nickel-plated brass |
Sensing surface | Polybutylene terephthalate (PBT) |
Clamping nuts | Nickel-plated brass |
Toothed washer | Zinc-plated iron |
Cable | Vinyl chloride (PVC) |
Accessories | Instruction manual, Clamping nuts, Toothed washer |
| Size | M8 | M12 | M18 |
| Shielded | Shielded |
Item | Model | E2E-X1R5D ⬜ | E2E-X2R5D ⬜ | E2E-X5D ⬜ |
Sensing distance | 1.5 mm ±10% | 2.5 mm ±10% | 5 mm ±10% |
Setting distance | 0 to 1.2 mm | 0 to 2 mm | 0 to 4 mm |
Differential travel | 10% max. of sensing distance |
Detectable object | Ferrous metal |
Standard sensing object | Iron, 10 × 10 × 1 mm | Iron, 12 × 12 × 1 mm | Iron, 18 × 18 × 1 mm |
Response frequency | 1,500 Hz | 1,000 Hz | 600 Hz |
Power supply voltage | 10 to 30 VDC, (including 10% ripple (p-p)) |
Leakage current | 0.8 mA max. |
Control output | Load current | 3 to 100 mA |
Residual voltage | Polarity: 3 V max. (Load current: 100 mA, Cable length: 2 m) No polarity: 5 V max. (Load current: 100 mA, Cable length: 2 m) |
Indicator | D1 Models: Operation indicator (orange), Setting indicator (green) D2 Models: Operation indicator (orange) |
Operation mode | D1 Models: NO D2 Models: NC |
Protection circuits | Surge suppressor, Load short-circuit protection |
Ambient temperature range | Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) |
Ambient humidity range | Operating and Storage: 35% to 95% (with no condensation) |
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range |
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case |
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case |
Vibration resistance (destruction) | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
Shock resistance (destruction) | 500 m/s 2 10 times each in X, Y, and Z directions | 1,000 m/s 2 10 times each in X, Y, and Z directions |
Degree of protection | Pre-wired Models/Pre-wired Connector Models: IP67 (IEC 60529), IP67G (JIS C 0920 Annex 1) Passed OMRON's Oil-resistant Component Evaluation Standards (Cutting oil type: specified in JIS K 2241:2000, Temperature: 35°C max.) and IEC 60529 (old standard: DIN 40050 PART9) IP69K |
Connecting method | Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models (Standard cable length: 0.3 m) |
Weight (packed state) | Pre-wired Models | Approx. 60 g | Approx. 70 g | Approx. 130 g |
Pre-wired Connector Models | Approx. 30 g | Approx. 40 g | Approx. 70 g |
Materials | Case | Stainless steel (SUS303) | Nickel-plated brass |
Sensing surface | Polybutylene terephthalate (PBT) |
Clamping nuts | Nickel-plated brass |
Toothed washer | Zinc-plated iron |
Cable | Vinyl chloride (PVC) |
Accessories | Instruction manual, Clamping nuts, Toothed washer |
Rated current | 4 A |
Rated voltage | 250 VDC |
Contact resistance (connector) | 40 mΩ max. (20 mV max., 100 mA max.) |
Insulation resistance | 1,000 MΩ min. (at 500 VDC) |
Dielectric strength (connector) | 1,500 VAC for 1 min (leakage current: 1 mA max.) |
Degree of protection | IP67 (IEC60529) |
Insertion tolerance | 50 times min. |
Lock strength | Tensile: 100 N/15 s, Torsion: 1 N·m/15 s |
Cable holding strength | Tensile: 100 N/15 s, Torsion: 1 N·m/15 s (for cable diameter of 6 mm) |
Lock operating force | 0.1 to 0.25 N·m |
Ambient operating temperature range | −25 to 70°C |
Ambient humidity range | 20% to 85% |
Number of pressure-weld repairs | 10 times max. (Limited to the same external diameter and wire diameter.) |